Nacalai USA - Innovations for Life Sciences

Subtotal: $0.00

View Cart

COSMOSIL PYE and COSMOSIL NPE

Specialty for Structual Isomers / π-π interaction, charge transfer and stereo selectivity

COSMOSIL PYE (pyrenylethyl group bonded) and COSMOSIL NPE (nitrophenylethyl group bonded) column show unique retention characteristics based on multiple separation modes such as hydrophobic, charge transfer and π-π interactions. These columns are recommended for the separation of structural isomers.

 COSMOSIL 5PYECOSMOSIL 5NPE
Silica gel high purity spherical porous silica
Average particle size 5µm
Average pore size approx. 120Å
Specific surface area approx. 300m²/g
Stationary phase 2-(1-pyrenyl)ethyl group nitrophenylethyl group
End capping treatment near-perfect treatment

 

Separation of PAHs

Due to the planar pyrene ring structure and strong π-π interactions, COSMOSIL PYE achieves excellent separation of aromatic isomers.

Sample: 1,2:3,4-Dibenzanthracene (CAS# 215-58-7), 1,2:5,6-Dibenzanthracene (CAS#53-70-3) 2,3-Benzofluorene (CAS#243-17-4), Acenaphthene (CAS#83-32-9), Acenaphthylene (CAS#208-96-8), Anthracene (CAS#120-12-7), Benzo[a]pyrene (CAS#50-32-8), Chrysene (CAS#218-01-9), Fluoranthene (CAS#206-44-0), Fluorene (CAS#86-73-7), Naphthacene (CAS#92-24-0), Naphthalene (CAS#91-20-3), Perylene (CAS#198-55-0), Phenanthrene (CAS#85-01-8), Pyrene (CAS#129-00-0), Tetraphene [Benz[a]anthracene] (CAS#56-55-3), Triphenylene (CAS#217-59-4)

 

Advantage of dipole-dipole interactions

COSMOSIL NPE retains 1, 8-dinitronaphthalene longer than 1, 5-dinitronaphthalene due to the dipole-dipole and π-π interactions.

Sample: 1,5-Dimethylnaphthalene (CAS#571-61-9), 1,5-Dinitronaphthalene (CAS#605-71-0), 1,8-Dinitronaphthalene (CAS#602-38-0), 1-Methylnaphthalene (CAS#90-12-0), Naphthalene (CAS#91-20-3)

Application

Sterols

 Sample: Campesterol (CAS#474-62-4), Cholesterol (CAS#57-88-5), Sitosterol (CAS#83-46-5), Stigmasterol (CAS#83-48-7)

 

Tocopherols

Sample: (+)-γ-Tocopherol (CAS#54-28-4), (+)-δ-Tocopherol (CAS#119-13-1), DL-α-Tocopherol (CAS#10191-41-0), DL-β-Tocopherol (CAS#148-03-8)

 

 

Usage Information

COSMOSIL PYE
 
Column5 µm PYE
I.D. (mm)2.03.04.610.020.0
Washing method 1. Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water.

2. (If you used a buffer, always do step 1 first!) Remove adsorbed compounds and fix unstable baselines by washing with methanol and/or THF.
Storage conditions Short-term (up to a week):
Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water.

Long-term:
Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. Then, replace the solvent with 70% methanol or acetonitrile : 30% water.

In either case, tightly plug the column, and store in a cool and dry place.
Usable pH range pH2~pH7.5
Max. pressure 20MPa 15MPa
Temperature range The maximum usable temperature is 60°C. However. for regular use, please use at a constant temperature between 20°C and 50°C.
Usable solvents

- Any solvent that will not dissolve the silica gel (such as alkaline solutions) or cleave the stationary phase (such as very acidic solutions) is usable.

- Methanol is the recommended mobile phase for COSMOSIL PYE. Acetonitrile is not recommended because it has many π-π electrons and interferes with π-π interactions between the sample and the stationary phasae.

Note: For solvents with high viscosity, please watch the system pressure and keep it below 20 MPa. Also, please wash the column after using acidic mobile phases or solvents with high freezing points.

Other instructions

- Buffer concentration is usually sufficient at 0.005 - 0.02 mol/L.

- Always filter mobile phases using a 0.5 µm or finer filter before use.

- As acetonitrile interferes with π electron interactions, please use a methanol-based mobile phase.

- The baseline may become unstable due to the high UV absorption of shedded stationary phase. If this occurs, please wash the column with THF (Tetrahydrofuran). A small amount of stationary phase shedding will not affect performance.

- This column is not suitable for gradient analysis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COSMOSIL NPE

Column5 µm NPE
I.D. (mm)2.03.04.610.020.0
Washing method 5 µm C18-MS-II
Storage conditions Short-term (up to a week):
Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. For example, if your mobile phase was 50:50 methanol/20 mmol/l phosphate buffer, wash with 50:50 methanol/water.

Long-term:
Remove buffer, salts and/or acid from column: wash for 10-15 min. using the mobile phase last used, without buffer, salts or acid. Then, replace the solvent with 70% methanol or acetonitrile : 30% water.

In either case, tightly plug the column, and store in a cool and dry place.
Usable pH range pH2~pH7.5
Max. pressure 20MPa 15MPa
Temperature range The maximum usable temperature is 60°C. However. for regular use, please use at a constant temperature between 20°C and 50°C.
Usable solvents

- Any solvent that will not dissolve the silica gel (such as alkaline solutions) or cleave the stationary phase (such as very acidic solutions) is usable.

- Methanol is the recommended mobile phase for COSMOSIL NPE. Acetonitrile is not recommended because it has many π-π electrons and interferes with π-π interactions between the sample and the stationary phasae.

Note: For solvents with high viscosity, please watch the system pressure and keep it below 20 MPa. Also, please wash the column after using acidic mobile phases or solvents with high freezing points.

Other instructions

- Buffer concentration is usually sufficient at 0.005 - 0.02 mol/L.

- Always filter mobile phases using a 0.5 µm or finer filter before use.

- As acetonitrile interferes with π electron interactions, please use a methanol-based mobile phase.

- The baseline may become unstable due to the high UV absorption of shedded stationary phase. If this occurs, please wash the column with THF (Tetrahydrofuran). A small amount of stationary phase shedding will not affect performance.

- This column is not suitable for gradient analysis.

COSMOSIL Application Search

COSMOSIL Application, which includes more than 7,700 applications using COSMOSIL/COSMOCORE columns, is now usable by clicking the link below which is in Nacalai Tesque, Inc. The application is searchable by sample category, sample name, CAS No., column name and particle size

Downloads

Ordering Information

COSMOSIL 3PYE
Product Description Cat.No. PKG Size Price  
COSMOSIL 3PYE Packed Column (2.0 mm I.D. x 150 mm) End-Fitting: Waters type
19080-51 1 pkg 1,552.00 Buy
COSMOSIL 3PYE Packed Column (4.6 mm I.D. x 150 mm) End-Fitting: Waters type
21165-81 1 pkg 1,552.00 Buy
COSMOSIL 5NPE
Product Description Cat.No. PKG Size Price  
COSMOSIL 5NPE Packed Column (1.0 mm I.D. x 150 mm) End-Fitting: Waters type
05897-01 1 pkg 1,070.00 Buy
COSMOSIL 5NPE Packed Column (2.0 mm I.D. x 100 mm) End-Fitting: Waters type
34500-71 1 pkg 899.00 Buy
COSMOSIL 5NPE Packed Column (2.0 mm I.D. x 150 mm) End-Fitting: Waters type
34328-51 1 pkg 958.00 Buy
COSMOSIL 5NPE Packed Column (2.0 mm I.D. x 250 mm) End-Fitting: Waters type
34379-91 1 pkg 1,359.00 Buy
COSMOSIL 5NPE Packed Column (4.6 mm I.D. x 100 mm) End-Fitting: Waters type
04673-51 1 pkg 1,006.00 Buy
COSMOSIL 5NPE Packed Column (4.6 mm I.D. x 150 mm) End-Fitting: Waters type
37902-21 1 pkg 958.00 Buy
COSMOSIL 5NPE Packed Column (4.6 mm I.D. x 250 mm) End-Fitting: Waters type
37990-71 1 pkg 1,349.00 Buy
COSMOSIL 5NPE Packed Column (10.0 mm I.D. x 250 mm) End-Fitting: Waters type
05469-11 1 pkg 4,024.00 Buy
COSMOSIL 5NPE Packed Column (20.0 mm I.D. x 150 mm) End-Fitting: Waters type
02638-81 1 pkg 11,706.00 Buy
COSMOSIL 5NPE Packed Column (20.0 mm I.D. x 250 mm) End-Fitting: Waters type
38046-21 1 pkg 14,623.00 Buy
COSMOSIL 5NPE Packed Column (28.0 mm I.D. x 250 mm) End-Fitting: Waters type
09553-71 1 pkg 32,047.00 Buy
COSMOSIL 5NPE Guard Column (4.6 mm I.D. x 10 mm) End-Fitting: Waters type
37904-01 1 pkg 450.00 Buy
COSMOSIL 5NPE Guard Column (10.0 mm I.D. x 20 mm) End-Fitting: Waters type
38045-31 1 pkg 899.00 Buy
COSMOSIL 5NPE Guard Column (20.0 mm I.D. x 20 mm) End-Fitting: Waters type
05868-81 1 pkg 3,328.00 Buy
COSMOSIL 5NPE Guard Column (20.0 mm I.D. x 50 mm) End-Fitting: Waters type
05869-71 1 pkg 3,799.00 Buy
COSMOSIL 5PYE
Product Description Cat.No. PKG Size Price  
COSMOSIL 5PYE Packed Column (1.0 mm I.D. x 50 mm) End-Fitting: Waters type
04681-41 1 pkg 1,236.00 Buy
COSMOSIL 5PYE Packed Column (1.0 mm I.D. x 150 mm) End-Fitting: Waters type
02851-71 1 pkg 1,552.00 Buy
COSMOSIL 5PYE Packed Column (2.0 mm I.D. x 50 mm) End-Fitting: Waters type
18864-21 1 pkg 1,338.00 Buy
COSMOSIL 5PYE Packed Column (2.0 mm I.D. x 100 mm) End-Fitting: Waters type
34501-61 1 pkg 1,194.00 Buy
COSMOSIL 5PYE Packed Column (2.0 mm I.D. x 150 mm) End-Fitting: Waters type
38042-61 1 pkg 1,552.00 Buy
COSMOSIL 5PYE Packed Column (2.0 mm I.D. x 250 mm) End-Fitting: Waters type
34450-31 1 pkg 2,092.00 Buy
COSMOSIL 5PYE Packed Column (4.6 mm I.D. x 50 mm) End-Fitting: Waters type
38043-51 1 pkg 1,054.00 Buy
COSMOSIL 5PYE Packed Column (4.6 mm I.D. x 100 mm) End-Fitting: Waters type
04672-61 1 pkg 1,349.00 Buy
COSMOSIL 5PYE Packed Column (4.6 mm I.D. x 150 mm) End-Fitting: Waters type
37837-91 1 pkg 1,440.00 Buy
COSMOSIL 5PYE Packed Column (4.6 mm I.D. x 250 mm) End-Fitting: Waters type
37989-11 1 pkg 2,103.00 Buy
COSMOSIL 5PYE Packed Column (10.0 mm I.D. x 250 mm) End-Fitting: Waters type
37996-11 1 pkg 6,586.00 Buy
COSMOSIL 5PYE Packed Column (20.0 mm I.D. x 150 mm) End-Fitting: Waters type
05948-31 1 pkg 18,549.00 Buy
COSMOSIL 5PYE Packed Column (20.0 mm I.D. x 250 mm) End-Fitting: Waters type
38044-41 1 pkg 24,889.00 Buy
COSMOSIL 5PYE Packed Column (28.0 mm I.D. x 250 mm) End-Fitting: Waters type
34300-91 1 pkg 52,644.00 Buy
COSMOSIL 5PYE Guard Column (2.0 mm I.D. x 10 mm) End-Fitting: Waters type
17787-71 1 pkg - Inquire
COSMOSIL 5PYE Guard Column (4.6 mm I.D. x 10 mm) End-Fitting: Waters type
37903-11 1 pkg 482.00 Buy
COSMOSIL 5PYE Guard Column (10.0 mm I.D. x 20 mm) End-Fitting: Waters type
38041-71 1 pkg 1,531.00 Buy
COSMOSIL 5PYE Guard Column (20.0 mm I.D. x 20 mm) End-Fitting: Waters type
05867-91 1 pkg 5,201.00 Buy
COSMOSIL 5PYE Guard Column (20.0 mm I.D. x 50 mm) End-Fitting: Waters type
34475-21 1 pkg 6,495.00 Buy